Tender For supply of various size of di- electrical safety shoes, electric shock resistant up to 30 kv as per attached specification. technical specification for art 9721w product: 30kv dielectric boot with steel toe. 1). size range : 6-9 2).type of construction vulcanized rubber upper and sole. 3).last/ sole pattern psv & vsv/ st 4).specialty tested individual boots at 30kv under wet condition 5).recommendation for working environment with high voltage hazards power station operations substation (step-up/ step-down/ distribution) operations electrical hazards with wet condition/ water exposure high current leakage hazardselectrical installations. 6). compliance- astm f2413-18 m i/c eh european standard ce approved ? en iso 20345 : 2011 (sb e fo hro sra) en 50321-1:2018 class 3 ac (for installations with nominal voltage up to 26500v a.c. sb = standard basic protection as per en iso 20345 e= heel energy absorption fo = fuel oil resistant outsole hro = resistant to hot contact sra =slip resistance on ceramic tile with sodium lauryl sulphate csa z195-14 / astm f 2413-18 grade 1 toe protection compression resistance, 11kn 18 kv electric shock resistance (esr) protection. 7). dielectric footwear* astm f1117-03(2013) (min 20,000vac) 8). lining material selected polyester grade lining comes with extra comfort and durability 9). upper construction leak-proof (electrically verified) reinforced rubber upper high visibility with orange and green contrast easy for cleaning. 10). sole / heel electrical shock resistant sole suitable for high voltage/ current environment slip resistant vulcanized rubber outsole good abrasion resistant for extra durability heel energy absorption design to minimize the heel impact. 11). steel toe cap epoxy coated toe caps for anti-corrosion meets csa z195 impact andastm f2413 compression tests. 12). chemical resistance sole & upper - good resistant towards acids and alkalis 13). finishing lacquer coating for weather protection. 14). packing recyclable polybag & 6pairs in a carton. various sizes of electrical safety shoe as per requirement (size 5-12) [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : design, engineering, procurement, material selection, manufacturing, inspection at vendor or subvendors works before dispatch, packing, shipping, delivery at site for indigenous equipment, insurance, unloading, handling and storage at site, assembly, erection, testing, commissioning, successful performance guarantee, handing over of the substation , power supply distribution system, illumination and street lighting system, providing diesel generator sets for extending alternate power supply at various locations in ytps colony town ship including residential and non-residential complexes with all accessories, mandatory spares, tools and tackles for ytps (5x800mw) colony township at veerlapalem (v), damercherla (m), nalgonda district of telangana, india
Tender For corrigendum : name of work:- shift of load of 11 kv feeder, paraspur of power substation, karanalganj rural to jarwal feeder in business plan 2026-27 under power distribution section-karnailganj areathe act of doing.
Tender For annual maintenance contract of installed e&m equipments in central drug standard control organization, gothapatna, bhubaneswar for financial year 2026-27. - & minor repairs of cctv & including, & minor repairs of kone lift i/c, (standard deviation colour matching), (standard deviation colour matching), (t.c.). manufactures word mark/, (unified glare rating) < 19, flicker, / 6500°k (as per ansi bin), sdcm, /6500°k (as per ansi bin),sdcm, <3,, <5, maximum power consumption, >85%, input voltage: 140-270 volt ac,, >85%, operating voltage ac 140-270, >85%, operating voltage ac 140-270, >85%,thd < 10% as per iec 61000-, 1 2,22,718.00 job 2,22,718.00 mr, 1 no 13 passenger lift,, 1.5 sq. mm frls/hffr, pvc, 10% , p. f.≥0.95, ip20, cri ≥80, ugr, 10.1 18 watt 10 618.00 each 6,180.00 mr, 10322 with driver as per the, 11.1 36 watt 10 2,103.00 each 21,030.00 mr, 12 13,877.00 month 1,66,524.00 mr, 12 16,961.00 month 2,03,532.00 mr, 12 21,586.00 month 2,59,032.00 mr, 12 24,086.00 month 289032 mr, 12 24,128.00 month 2,89,536.00 mr, 12 31,890.00 month 382680 mr, 12 4,490.00 month 53,880.00 mr, 12 53,452.00 month 6,41,424.00 mr, 125 kva dg set with amf and, 15u rack 1 13,330.00 nos 13,330.00, 2 x 6 sockets 16a power distribution, 2.5 kv with short & open circuit, 3-2, p. f.≥0.95, ip-66,ik-10, cri >70,, 39.23.3, 4000°k/ 5700°k /6500°k (as per ansi, 61000-4-5, driver efficiency, 70% of initial lumen maintained till life, 70% of initial lumen maintained till life, 90°c)., 90°c)., above 90°c)., aluminium body including trim, aluminium body with driver as per the, and earthing etc. as required with, annual comprehensive maintenance, annual comprehensive, maintenance, annual comprehensive, maintenance, approved by engineer-in-charge as, approved by engineer-in-charge as, approved by engineer-in-charge as, as required, as required., at gothapatna as required, attached & following staff., basis as per terms & conditions, basis) including servicing, preventive, bin), sdcm (standard deviation, bis standard complete in all respect, bis standards and trade mark, body material with pmma and, cable and earthing etc. as required, cable and earthing etc. as required, cables, nvr, switch, cctv camera,, cct 3000°k / 4000°k / 5700°k, cdtl building etc. as reqd., centigrade, internal surge protection of, certificate (t.c.). manufactures word, circuitry) of minimum 50000 burning, colour matching) <3,, commissiong of pa, rectification and, comprehensive and repair, comprehensive and repair, comprehensive and repair, condition at cdtl office building etc, contract (as inspection on monthly, copper conductor single core cable, day electrical complaints, complaint, distribution pane, 250 kva substation,, down lighter (round/ square/, driver & electrical circuitry), of, dsr-25, efficacy ≥105 <120 lm/watt) supplying, ends , cct 3000°k / 4000°k / 5700°k, ends as per lm80 extrapolation ies, entire lift , etc in cdtl office building, etc in cdtl office at gothapatna as, extrapolation ies tm-21-11 report,, fixture shall be confirming to relevant, fixture shall be of relevant bis, fixtures as per bis shall be submitted., fixtures as per bis shall be submitted., fixtures as per bis shall be submitted., free, (flicker should be below 5 %), life, frequency 50/60 hz, operating temp, general shift) at cdsco on monthly, hours with70% of initial lumen, housing such that led, housing such that led junction, housing such that led junction, i/c external connections with 1.5, in all respect i/c external connections, inspection on monthly basis) including, inspection on monthly basis) including, insulated copper conductor single core, insulated copper conductor single core, internal surge protection of 2.5 kv with, ip surveillance systems i/c maintance, ip20, cri ≥80 , ugr (unified glare, junctiontemperature shall not rise, knocked-down condition (ckd) shape,, led panel light 2x2 ft. (system lumen, lenses for beam angle asper iesna, life time (led, driver &
Tender For under the business plan 2026&27 plan in the jurisdiction of electricity urban distribution division [buludahar], the work of installing detection device from safety point of view at 33@11 kv power substation.
Tender For restoration of electrical supply by locating and repairing faults in the underground power cable feeding from substation to crl, including servicing and maintenance of the electrical distribution panel at central reference library (crl), d.u.
Tender For supply of various size of di- electrical safety shoes, electric shock resistant up to 30 kv as per attached specification. technical specification for art 9721w product: 30kv dielectric boot with steel toe. 1). size range : 6-9 2).type of construction vulcanized rubber upper and sole. 3).last/ sole pattern psv & vsv/ st 4).specialty tested individual boots at 30kv under wet condition 5).recommendation for working environment with high voltage hazards power station operations substation (step-up/ step-down/ distribution) operations electrical hazards with wet condition/ water exposure high current leakage hazardselectrical installations. 6). compliance- astm f2413-18 m i/c eh european standard ce approved ? en iso 20345 : 2011 (sb e fo hro sra) en 50321-1:2018 class 3 ac (for installations with nominal voltage up to 26500v a.c. sb = standard basic protection as per en iso 20345 e= heel energy absorption fo = fuel oil resistant outsole hro = resistant to hot contact sra = slip resistance on ceramic tile with sodium lauryl sulphate csa z195-14 / astm f 2413-18 grade 1 toe protection compression resistance, 11kn 18 kv electric shock resistance (esr) protection. 7). dielectric footwear* astm f1117-03(2013) (min 20,000vac) 8). lining material selected polyester grade lining comes with extra comfort and durability 9). upper construction leak-proof (electrically verified) reinforced rubber upper high visibility with orange and green contrast easy for cleaning. 10). sole / heel electrical shock resistant sole suitable for high voltage/ current environment slip resistant vulcanized rubber outsole good abrasion resistant for extra durability heel energy absorption design to minimize the heel impact. 11). steel toe cap epoxy coated toe caps for anti-corrosion meets csa z195 impact and astm f2413 compression tests. 12). chemical resistance sole & upper - good resistant towards acids and alkalis 13). finishing lacquer coating for weather protection. 14). packing recyclable polybag & 6 pairs in a carton. various sizes of electrical safety shoe as per requirement (size 5-11) [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : supply of supply part for retrofitting of lt panel by supply and installation , service part for retrofitting of lt panel by supply and installation , supply of main incoming lt power distribution panels slipway , install, replace, test and commissioning of main incoming lt power distribution panels slipway , supply of welding and lighting panels slipway , install, replace, test and commissioning of welding and lighting panels slipway , supply of 3.5c x 400 sq.mm aluminum cable from substation-02 to slipway , laying, fixing, testing and commissioning of 3.5c x 400 sq.mm aluminum cable from substation-02 to slipway , supply of 3.5cx 185 sq.mm aluminum cable from slipway-2 and 3 main incoming panels to welding and lighting panels , laying, fixing, testing and commissioning of 3.5cx 185 sq.mm aluminum cable from slipway-2 and 3 main incoming panels to welding and lighting panels , supply and fitment of suitable end termination kits - straight through joints kits of required quantity to all the incoming and outgoing cables at both ends of slipway-02, slipway-03, substations, etc , providing earth pits with 75mm ci pipe as is standards , supply and laying of gi flat 50 x10 mm necessary joints with nut and bolts from earth pit to panel boards , repair and excavation of cable trench of 75mm thick up to 90cm depth , fixing of perforated cable tray on slipways 02 and 03 and securing of cables with metal ties and capping and casing to be provided , foundation for all lt panels i.e. steel foundations with concrete pedestal for panels all incoming and welding and lighting panels
Tender For various size of di- electrical safety shoes, tested individual boots at 30kv under wet condition for working environment with high voltage hazards power station operations substation (step-up/ step-down/distribution) operations electrical hazards with wet condition/ water exposure high current leakage hazards electrical installations.s.as per specification attached.note:sample may got approved by consignee before bulk supply. [ warranty period: 30 months after the date of delivery ] ]
Tender For etno-17/edc-1/mt/2026-27-within the jurisdiction of the electricity distribution division-i, meerut—specifically under the purview of the sub-divisional officer, electricity distribution sub-division-i, bagpat road—the scope of work encompasses various tasks undertaken for safety considerations beneath the 33/11 kv mohiuddinpur power substation. these tasks include the replacement of dilapidated poles and wires; the relocation of double-pole structures; the installation of fencing around transformers; the construction of plinths for transformers; the erection of new 11 kv lines; the application of 11 kv jointing kits; the dismantling of low tension (lt) and high tension (ht) lines; and the overall strengthening of lt and ht distribution networks, among other related activities.